Typical applications include:
- Cooking and thermal processing
- Evaporation and concentration
- Distillation and fermentation-related utilities
- Oilseed conditioning and refining
- Process heating
- Hot-water production
In a steam-oriented configuration, one standard WARP module supports the following indicative steam production ranges:
- ~20–31 t/h using qualified RDF/SRF
- ~17–25 t/h using prepared MSW-derived fuel
Steam output from agricultural residues and biomass is established separately according to the qualified fuel characteristics and boiler configuration.
For brownfield facilities, the existing steam header provides a defined integration point.
Conventional boilers can remain available for start-up, peak demand, maintenance and redundancy.
WARP can therefore be sized against the facility's stable base-load steam requirement rather than its maximum instantaneous demand.
Under a Steam-as-a-Service structure, the contracted energy product can be specified directly as:
X t/h of steam at Y barg and Z°C at the customer's battery limit.